volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Canister Purge Control Valve|Locations|Page 5831 > < Canister Purge Control Valve|Locations|Page 5829
Page 2
background image

Specified value: 10.6 volts +/- 2 volts.

Turn the ignition switch OFF.

If the specified value was Not obtained:

-

Leave the multimeter positive lead on terminal 1 and connect the multimeter negative lead to engine ground.

-

Engine still running.

Specified value: 10.6 volts +/- 2 volts.

Turn the ignition switch OFF.

If the specified value was Not obtained:

-

Remove fuse S-243. Check the wire from the electrical harness connector terminal 1 to fuse S-243 for open or high resistance.

-

Check the electrical harness connector for damage, corrosion, loose or broken terminals.

-

If necessary, repair the wiring connection.

If the specified value was obtained:

Check Ground activation 

If the manufacturers test box is being used, perform the following step.

-

Install the test box. 

If the manufacturers test box is not being used, perform the following step.

-

Remove the Motronic Engine Control Module (ECM) ( J220). Refer to the Repair Information.

-

Using a multimeter, check the Evaporative Emission (EVAP) Canister Purge Regulator Valve (N80) electrical connector terminal 2 to Motronic
Engine Control Module (ECM) (J220 ) electrical connector T121 terminal 64 for an open circuit.

Canister Purge Control Valve|Locations|Page 5831 > < Canister Purge Control Valve|Locations|Page 5829