volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Oxygen Sensor Before Catalytic Converter, Checking Heater|Page 5373 > < Oxygen Sensor Before Catalytic Converter, Checking Heater|Page 5371
Page 1
background image

Oxygen Sensor: Testing and Inspection
Oxygen Sensor In Center Catalytic Converter Checking, BPR Engine Only

Diagnostic Procedures

Oxygen Sensor in Center Catalytic Converter Checking, BPR Engine Only

‹› This diagnostic only applies to the California Emissions BPR engine using 3 HO2S sensors. Use only gold-plated terminals when servicing

terminals in the electrical harness connectors of the Oxygen Sensor (O2S) 2 in center Three Way Catalytic Converter (TWC) (G465).

Special tools, testers and auxiliary items required

‹›  Multimeter.

‹› Wiring diagram.

Test requirements

‹› Fuse S-243 is OK.

‹› Engine Control Module (ECM) (J220) fuses OK.

‹› Battery voltage at least 12.5 volts.

‹› All electrical consumers such as, lights and rear window defroster, switched off.

‹› Vehicles with automatic transmission, shift selector lever into position " P" or "N".

‹› A/C switched off.

‹› Ground connections between engine/transmission/chassis OK.

‹› Ignition switched off.

Test procedure

-

Perform a preliminary check to verify the customers complaint. Refer to => [ Preliminary Check ] See: Testing and Inspection/Scan Tool Testing
and Procedures/Preliminary Check.

Start diagnosis

-

Perform the function test in Diagnostic Mode 06.

If specified values are obtained:

-

Check for possible intermittent connection or rub through of harness. 

-

Erase the code. Drive the vehicle and generate the readiness code. 

If the specified values are not obtained:

Checking primary voltage

-

Remove the black plastic cover (right side) underneath the vehicle to access the O2S connector.- arrows -.

-

Disconnect the Oxygen Sensor (O2S) 2 in center Three Way Catalytic Converter (TWC) (G465) electrical harness connector. 

-

Switch the ignition ON.

-

Using a multimeter, check the Oxygen Sensor (O2S) 2 in center Three Way Catalytic Converter (TWC) (G465) electrical harness connector
terminals 3 to 4 for voltage.

Specified value: 0.400 to 0.500 Volts

-

Switch the ignition OFF.

Oxygen Sensor Before Catalytic Converter, Checking Heater|Page 5373 > < Oxygen Sensor Before Catalytic Converter, Checking Heater|Page 5371