volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Oxygen Sensor & O2 Sensor Regulation After Converter, Check|Page 4329 > < Oxygen Sensor & O2 Sensor Regulation After Converter, Check
Page 2
background image

Read measuring value block 30

->

1

2

-

Check status of oxygen sensor control after Three Way Catalytic Converter (TWC) (display zone 2).

Specification: 1 1 0

Significance of 3 digit number block in display zone 2

If the specification is obtained:

-

Change to display group 36 as follows:

-

Press -> button.

-

Press buttons -0- and -4- for "Basic Setting" function and confirm entry with -Q- button.

Indicated on display

Basic setting
Input display group number XXX

-

Press buttons -0-, -3- and -6- for "Display group number 36" and confirm entry with -Q- button.

Indicated on display (1 to 2 = Display zones)

System in basic setting 36

->

1

2

-

Check oxygen sensor voltage after Three Way Catalytic Converter (TWC) in display zone 1.

Specification: 0.100...0.900 V (can fluctuate slightly)

Oxygen Sensor & O2 Sensor Regulation After Converter, Check|Page 4329 > < Oxygen Sensor & O2 Sensor Regulation After Converter, Check