volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Oxygen Sensor & O2 Sensor Regulation After Converter, Check|Page 3268 > < Oxygen Sensor & O2 Sensor Regulation After Converter, Check|Page 3266
Page 8
background image

-

VAG 1526 hand multimeter or VAG 1715 multimeter

-

VAG 1594 adapter set

-

Electrical Wiring Diagram

Test conditions

-

All fuses must be OK

-

Battery voltage must be at least 11.5 V

-

Exhaust system between Three Way Catalytic Converter (TWC) and cylinder head must be free of leaks

-

Engine Coolant Temperature (ECT) must be at least 80 °C, see display group 04, display zone 3

Functional check

-

Connect VAG 1551 scan tool ((VAG 1552). Start engine and select "Address word" 01 of Motronic Engine Control Module (ECM) -J220-.
Engine must be running at idle speed. Connecting scan tool and selecting Motronic Engine Control Module (ECM) -J220-. See: Computers and
Control Systems/Testing and Inspection/Reading and Clearing Diagnostic Trouble Codes/Scan Tool Connecting/With Manufacturer's Scan
Tool/Connecting VAG 1551 Scan Tool 

Indicated on display

Rapid data transfer

HELP

Select function XX

-

Press buttons -0- and -8- for function "Read measuring value block" and confirm entry with -Q- button.

Indicated on display

Read measuring value block
Input display group number XXX

-

Press buttons -0-, -3- and -0- for "Display group number 30" and confirm entry with -Q- button.

Indicated on display (1 to 2 = Display zones)

Read measuring value block 30

->

1

2

-

Check status of the oxygen sensor control before Three Way Catalytic Converter (TWC) (display zone 1):

Specification: 1 1 1

Oxygen Sensor & O2 Sensor Regulation After Converter, Check|Page 3268 > < Oxygen Sensor & O2 Sensor Regulation After Converter, Check|Page 3266