volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Oxygen Sensor & O2 Sensor Regulation After Converter, Check|Page 3271 > < Oxygen Sensor & O2 Sensor Regulation After Converter, Check|Page 3269
Page 11
background image

If the specification is obtained:

-

Press -> button.

-

Press buttons -0- and -6- for function "End output" and confirm entry with -Q- button.

-

Switch off ignition.

Continuation

If the oxygen sensor control in display zone 1 does not fluctuate as stated:

-

Press -> button.

-

Press buttons -0- and -6- for function "End output" and confirm entry with -Q- button.

-

Test drive vehicle to remove possible residue on oxygen sensor and repeat check.
Observe the valid safety precautions when carrying out a road test.
If the the specifications in display zone 1 are not obtained even after a test drive, or the value does not fluctuate by at least 2 %:

-

Check oxygen sensor before Three Way Catalytic Converter (TWC) for aging.   See: Computers and Control Systems/Testing and
Inspection/Component Tests and General Diagnostics/Oxygen Sensor Before Three-Way Catalytic Converter Aging, Check

Evaluating display zone 33, display zones 1 - oxygen sensor control learned values before Three Way Catalytic Converter (TWC)

Oxygen Sensor & O2 Sensor Regulation After Converter, Check|Page 3271 > < Oxygen Sensor & O2 Sensor Regulation After Converter, Check|Page 3269