New Beetle GLS L4-1.9L DSL Turbo (ALH) (2002)
-
Clamp suction hose using 3094 hose clamp.
-
Place drip tray underneath.
-
Disconnect bracket for pump pressure line from cylinder block.
-
Disconnect pump pressure line.
-
Install adapter -1- (use seal).
1. VAG1402/1 A
2. VAG1402/6 adapter hose
-
Connect VAG1402 pressure gauge.
1. VAG1402 pressure gauge
2. VAG1402/6 adapter hose
3. Banjo bolt
4. Pressure hose banjo union
5. VAG1402/2 adapter set
6. Hose from VAG 1402 pressure gauge
-
Remove 3094 hose clamps from suction and return hoses.
-
Start engine and if necessary add fluid to reservoir.
-
Turn steering wheel approximately 10 times from lock-to-lock.
-
Check delivery pressure.
Test requirements
-
Ribbed belt and ribbed belt tension OK
-
System not leaking
-
Hoses/lines are not kinked or restricted
-
With engine running at idle speed, close cut-off valve (not longer than 5 seconds) and read off pressure.
Specifications
-
Gasoline engines: 85 - 95 bar (1233 - 1378 psi)