volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Operational Readiness Oxygen Sensor|Page 2430 > < Operational Readiness Oxygen Sensor|Page 2428
Page 22
background image

-

Set multimeter to measure resistance and check sensor heating resistance at connector to oxygen sensor terminals 3 + 4
Specification: 2.5 to 10 Ohms (at room temperature).

If the specification is not obtained:

-

Replace oxygen sensor before catalyst (G39).

-

Check DTC memory, if necessary, repair any malfunctions and then erase DTC memory. Refer to "Displaying and Reading Trouble Codes/With
Manufacturers Scan Tool/DTC Memory Checking and Erasing" See: Testing and Inspection 

If the oxygen sensor has continuity:

-

Set multimeter to measure voltage and connect to terminal 3 (connector to engine control module) and Ground.

-

Start engine and run at idle speed.

-

Measure voltage supply:
Specification: 11.0 to 14.5 V

If the specification is not obtained:

-

Check wiring between terminal 3 and fuel pump relay (J17) using wiring diagram.

If the specification is obtained:

Checking voltage supply

Operational Readiness Oxygen Sensor|Page 2430 > < Operational Readiness Oxygen Sensor|Page 2428