Check wires between test box and 4-pin connector (to control module) for open circuit according to wiring diagram.
-

Terminal 3 + socket 68

-

Terminal 4 + socket 69

-

Wire resistance: max. 1.5 Ohms

Continuation for all vehicles

-

Also check wires for short circuit to B+ and Ground (GND). Specified value: Infinite Ohms

If no malfunctions are found in wires:

-

Replace Motronic Engine Control Module (ECM) -J220-.

With Manufacturer Scan Tool

Oxygen Sensor And Sensor Control After Catalyst, Checking

NOTE:

-

Raise vehicle to reach oxygen sensor connector.

-

Only gold-plated terminals must be used to repair the terminals 3 and 4 in the connector for the oxygen sensor.

Special tools and equipment

-

Scan tool VAG 1551 or vehicle system tester V.A.G 1552 with cable VAG 1551/3B

-

Test box V.A.G 1598/31

-

Hand multimeter V.A.G 1526 or multimeter V.A.G 1715

-

Adapter set V.A.G 1594

-

Wiring diagram

Check conditions

-

All fuses must be OK

-

The battery voltage must be at least 11.5 V.

-

Exhaust system between catalyst and cylinder head must be free of leaks

-

Coolant temperature must be at least 85 °C, see display group 04, display zone 3