volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Operational Readiness Oxygen Sensor|Page 757 > < Operational Readiness Oxygen Sensor|Page 755
Page 22
background image

-

Remove protective cover -arrows- and separate 6-pin connector (black) -1- to oxygen sensor before catalyst (G39).

-

Set multimeter to measure resistance and check sensor heating resistance at connector to oxygen sensor terminals 3 + 4
Specification: 2.5 to 10 Ohms (at room temperature).

If the specification is not obtained:

-

Replace oxygen sensor before catalyst (G39).

-

Check DTC memory, if necessary, repair any malfunctions and then erase DTC memory. Refer to "Displaying and Reading Trouble Codes/With
Manufacturers Scan Tool/DTC Memory Checking and Erasing" See: Powertrain Management/Computers and Control Systems/Testing and
Inspection 

If the oxygen sensor has continuity:

Operational Readiness Oxygen Sensor|Page 757 > < Operational Readiness Oxygen Sensor|Page 755