volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Starting and Charging|Service and Repair > < Initial Inspection and Diagnostic Overview|Page 4199
Page 14
background image

checked.

-

Review noted values and compare with values in table.

-

Electrolyte density must be at least 1.24 kg/cu.dm.

-

If specific density is too low, charge battery and recheck specific density afterwards.

-

Electrolyte density must not vary more than 0.04 kg/cu.dm between cells.

Examples of unacceptable variations in specific gravity:

Example 1: Specific gravity in cell 4 (1.10) is too low.
Example 2: Specific gravity in cells 4 (1.10) and 5 (1.18) are too low and variation between cells exceeds  0.04 kg/cu.dm.

If specific gravity specifications are not met, replace battery.
If specific gravity specifications are met, reinstall cell caps

CAUTION!
Only the use of genuine VW battery cell caps ensures the different battery cover systems are sealed correctly. Only use genuine cell caps of the
same construction if lost or damaged. All cell caps must be equipped with an O-ring seal

Starting and Charging|Service and Repair > < Initial Inspection and Diagnostic Overview|Page 4199