New Beetle Turbo S L4-1.8L Turbo (AWP) (2002)
-
Depress accelerator slowly until full throttle position and observe angles displayed in display zones 1 and 2:
-
Percent figure in display zone 1 must rise continuously and evenly. Full tolerance range 10 to 88 % is not always displayed.
-
Percent figure in display zone 2 must fall continuously and evenly. Full tolerance range 89 to 11 % is not always displayed.
NOTE:
-
The reason why the display in display zone 1 rises and the display in display zone 2 falls is because the potentiometers (angle sensors) in the angle
sensors run in opposite directions.
-
The voltage of angle sensor 1 moves toward 5 volts. (The more the throttle valve is opened the higher the voltage; percentage increases).
-
While the voltage of angle sensor 2 drops from 5 volts toward 0 volt. (The more the throttle valve is opened the lower the voltage; percentage
falls).
If the specifications are obtained:
-
Press -> button.
-
Press buttons -0- and -6- for function "End output" and confirm entry with -Q- button.
-
Switch off ignition.
Continuation
If the displays do not indicate as described:
-
Press -> button.
-
Press buttons -0- and -6- for function "End output" and confirm entry with -Q- button.
-
Switch off ignition.
-
Disconnect 6-pin connector from Throttle Valve Control Module -J338- -arrow-.