Air Injection Control Valve: Testing and Inspection

Combination Valve, Checking

Recommended special tools and equipment

-

VAG1390 Hand Vacuum Pump

Test requirements

-

No leaks in vacuum lines or hose connections.

-

Vacuum hoses not clogged or kinked

-

Pressure hose for Secondary Air Injection (AIR) Pump Motor not clogged or kinked

Test sequence

NOTE:  Do not use pressurized air for the following test.

-

Disconnect vacuum hose -1- at Secondary Air Injection (AIR) Solenoid Valve -N112- -2-.

-

Disconnect pressure hose -3- at Secondary Air Injection (AIR) pump motor and blow air in with light pressure (arrow).
Combination valve must close.

NOTE:  To disengage, compress the buttons at the hose coupling.

-

Operate vacuum pump.
Combination valve must open.

If the combination valve does not open or it is constantly open:

-

Replace combination valve, item 2.

Air Injection Pump > < Air Injection Vacuum Control Solenoid Valve|Locations|Page 2950