New Beetle Turbo S L4-1.8L Turbo (AWP) (2002)
If no wiring malfunction is found:
-
Replace Motronic Engine Control Module (ECM) -J220-.
With Generic Scan Tool
Check Oxygen Sensor And Oxygen Sensor Regulation Behind Catalytic Converter
NOTE:
-
Vehicle must be raised before connector for oxygen sensor is accessible.
-
When servicing terminals 3 and 4 in harness connector of Heated Oxygen Sensor (HO2S), use only gold-plated terminals.
Recommended special tools and equipment
-
VAG1526 multimeter or VAG1715 multimeter
-
VAG1594 connector test kit
-
Wiring diagram
Test requirements
-
The respective fuses of Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) -G130- must be OK.
-
Battery voltage must be at least 11.5 volts.
-
All electrical consumers such as, for example, lights and rear window defroster must be switched off.
-
Parking brake must be engaged or else daylight driving lights will be switched on.
-
If vehicle is equipped with an A/C system, it must be switched off.
-
Ground (GND) connections between engine and chassis must be OK.
-
Exhaust system must be properly sealed between catalytic converter and cylinder head.
-
Coolant temperature must be at least 80 degrees C, Diagnostic mode 1: Check measuring values; PID 5, Coolant temperature. See: Powertrain
Management/Computers and Control Systems/Testing and Inspection/Scan Tool Testing and Procedures/With Generic Scan Tool/Diagnostic
Mode 1: Check Measured Values
-
Oxygen sensor heater for oxygen sensors behind catalytic converter must be OK, check. See: Powertrain Management/Computers and Control
Systems/Testing and Inspection/Component Tests and General Diagnostics/Oxygen Sensor, Checking/Oxygen Sensor Behind Catalyst,
Checking/Heater Check
Function test
-
Select the following output of oxygen sensor signals and check whether the specified values are being reached, Diagnostic mode 5: Check output
of oxygen sensor signals. See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Scan Tool Testing and
Procedures/With Generic Scan Tool/Diagnostic Mode 5: Check Output of Oxygen Sensor Signals
-
Check the specified values of the output of oxygen sensor signals at idle:
If specified values are obtained:
-
End diagnosis and switch ignition off.
If specified values are not obtained:
-
End diagnosis and let engine continue to run at idle.
-
Check primary voltage.
Checking primary voltage