Airbag control unit -J234- can be found behind console on tunnel. It is equipped with a fault memory. Connection for self-diagnosis can be found on right next to ignition switch. |
Control unit detects faults in airbag system and stores them in a non-volatile memory. |
When the ignition is switched on, the airbag warning lamp -K75- lights up for about 3 seconds and then goes out again. |
If the airbag warning lamp -K75- does not go out again, the voltage supply to the airbag control unit (J 234) has an open circuit. Fault rectification → Chapter. |
If there is a fault, the airbag warning lamp -K75- lights up again. |
At start of fault finding, initiate self-diagnosis and interrogate stored information using fault reader -V.A.G 1551-. |
Fault information displayed makes reference via fault table with notes to possible causes of fault for purposes of targeted repairs. |
|
|
|