Before operating the air conditioning system after recharging with refrigerant > < Basics for working on refrigerant circuit
O-ring
O-ring
t  Use only O-rings that are resistant to refrigerant R134a and related refrigerant oils. O-rings are no longer colour-coded. Coloured and black O-rings are used.
t  Check that the O-rings used have the correct internal diameters.
→ Rep. gr.87
→ Parts catalogue
t  Do not reuse seals!
t  Before fitting a seal, coat it lightly with refrigerant oil (PAG oil).
  Note
t  When purging components with compressed air and nitrogen, always collect the gas mixture exiting the component with suitable exhaust gas extraction equipment (workshop fume extractor).
t  After completing repair work, screw sealing caps (with seals) onto valve and service connections.
Before operating the air conditioning system. Check the vehicle-specific charge quantities → Rep. gr.87.
Do not top up a charged refrigerant circuit; discharge refrigerant present and recharge system.
   

Before operating the air conditioning system after recharging with refrigerant > < Basics for working on refrigerant circuit