Passat (B3)
If the fuel pump does not run:
Note: If the relay cannot be removed from the relay plate without tools then first disconnect battery earth strap.
Fuel pumps run:
=> Repair group 01; Self-diagnosis; Final control diagnosis Fuel pump does not run:
|
LED does not light up:
LED lights up (voltage supply OK.):
If not open circuit can be found:
Checking delivery rate Test conditions
Test sequence
Warning!
Fuel supply lines are under pressure! Before removing from hose connection wrap a cloth around the connection. Then release pressure by carefully pulling hose off connection.
|
|
*) Minimum delivery cm3/30 seconds **) Voltage at fuel pump with engine stationary and pump running (approx. 2 volts less than battery voltage). Example: During the test a voltage of 12.5 volts is measured at the battery. As the voltage at the pump is approx. 2 volts less than the battery voltage then this will equate to a minimum delivery of 530 cm3/30 s. If the minimum delivery rate is not attained:
|
If the minimum delivery rate is now attained:
If the minimum delivery rate is again not attained:
Only when up to now no fault has been detected:
If the delivery rate has been attained but nevertheless you suspect a fuel supply system fault (e.g. intermittent failure of fuel supply system):
|
Warning!
Danger of spray when opening the cut-offtap, hold container over the pressure gauge free connection.
If the pressure drops further:
If no wiring fault is detected:
|