volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Overview of selectable display groups; significance of display zones and display possibilities > < Measured value blocks
Read measured value block
Read measured value block
–  Initiating immobilizer self-diagnosis → Chapter.
   
Indicated on display:
–  Press “08 - Read measured value block” on the display -arrow-.
  N01-0480
Indicated on display:
–  Press number of data block to be read on number block on display -arrow- and confirm entry with “Q” key.
Example of measured value block contents
–  Press “0, 0 and 1” on number block on display and confirm input with “Q” key.
  N02-0547
Indicated on display:
If there is a “0” in the first display zone then the reader coil is faulty.
If there is a “1” in the first display zone then the reader coil is OK.
  N01-0582

Overview of selectable display groups; significance of display zones and display possibilities > < Measured value blocks