volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Electronic Power Control (EPC) Warning Lamp, Checking|Page 13276 > < Electronic Power Control (EPC) Warning Lamp, Checking|Page 13274
Page 2
background image

-

The respective fuses of Malfunction Indicator Lamp (MIL) -K83- must be OK

Test sequence

-

Switch on ignition:
exhaust MIL must light up.

If exhaust MIL does not light up when ignition is switched on:

-

Switch ignition off.

-

Check wire from ECM to exhaust MIL as follows:

-

Connect test box to control module wiring harness, connect test box for wiring test. See: Powertrain Management/Computers and Control
Systems/Testing and Inspection/Reading and Clearing Diagnostic Trouble Codes/Scan Tool Connecting/Test Box, Connecting For Wiring Test

Vehicles with engine code AEB

-

Bridge sockets 2 + 17 of test box with the respective adapter cables.

Vehicles with engine code ATW, AUG, AWM

-

Bridge sockets 2 + 47 of test box with the respective adapter cables.

Continuation for all vehicles

-

Switch on ignition:
exhaust MIL must light up.

If Malfunction Indicator Lamp (MIL) does not light up:

-

Switch ignition off.

-

Remove instrument cluster:

-

Check wire connection from Engine Control Module (ECM) to Malfunction Indicator Lamp (MIL) -K83- according to wiring diagram:

-

Erase DTC memory of Engine Control Module (ECM). Diagnostic mode 4: Reset/erase diagnostic data. See: Powertrain Management/Computers
and Control Systems/Testing and Inspection/Scan Tool Testing and Procedures/With Generic Scan Tool/Diagnostic Mode 4: Reset/Erase
Diagnostic Data

-

Generate readiness code. See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles and
Readiness Codes

If no malfunctions are detected in wire from Engine Control Module (ECM) to Malfunction Indicator Lamp (MIL):

-

Replace Motronic Engine Control Module (ECM) -J220-.

If exhaust MIL does not light up when ignition is switched on:

-

Start engine and let run at idle:
Exhaust MIL must go out after a few seconds.

If Malfunction Indicator Lamp (MIL) does not go out:

-

Switch ignition off.

-

Remove instrument cluster:

-

Connect test box to control module wiring harness. connect test box for wiring test. See: Powertrain Management/Computers and Control
Systems/Testing and Inspection/Reading and Clearing Diagnostic Trouble Codes/Scan Tool Connecting/Test Box, Connecting For Wiring Test

Vehicles with engine code AEB

-

Check wire connection between test box socket 17 and instrument cluster for short circuit to Ground (GND) according to wiring diagram:

Vehicles with engine code ATW, AUG, AWM

-

Check wire connection between test box socket 47 and instrument cluster for short circuit to Ground (GND) according to wiring diagram:

Continuation for all vehicles

-

Erase DTC memory of Engine Control Module (ECM). Diagnostic mode 4: Reset/erase diagnostic data. See: Powertrain Management/Computers

Electronic Power Control (EPC) Warning Lamp, Checking|Page 13276 > < Electronic Power Control (EPC) Warning Lamp, Checking|Page 13274