Oxygen Sensor: Testing and Inspection
Oxygen Sensor (O2S) and Oxygen Sensor Control Before Three Way Catalytic Converter (TWC),
Checking

Oxygen Sensor (O2S) And Oxygen Sensor Control Before Three Way Catalytic Converter (TWC), Checking

NOTE:  When servicing terminals in harness connector of Heated Oxygen Sensor (HO2S), use only gold-plated terminals.

Recommended special tools and equipment

-

V.A.G 1526 portable multimeter or V.A.G 1715 multimeter

-

V.A.G 1594 connector test kit

-

Wiring diagram

Test requirements

-

The respective fuses of Heated Oxygen Sensor (HO2S) -G39- must be OK:

-

Battery voltage must be at least 11.5 volts.

-

All electrical consumers such as, lights and rear window heating must be switched off.

-

Parking brake must be engaged or else daylight driving lights will be switched on.

-

If vehicle is equipped with an A/C system, it must be switched off.

-

Ground (GND) connections between engine and chassis must be OK.

-

Exhaust system must be properly sealed between catalytic converter and cylinder head.

-

Coolant temperature must be at least 80 degrees C, Diagnostic mode 1: Check measuring values; PID 5, Coolant temperature. See: Testing and
Inspection/Scan Tool Testing and Procedures/With Generic Scan Tool/Diagnostic Mode 1: Check Measuring Values

-

Oxygen sensor heaters for oxygen sensors before catalytic converter must be OK, check. See: With Generic Scan Tool/Components,
Checking/Oxygen Sensor Heater For O2 Sensors Before (TWC), Checking

Function test

-

Select the following output of oxygen sensor signals and check whether the specified values are being reached, Diagnostic mode 5: Check output
of oxygen sensor signals. See: Testing and Inspection/Scan Tool Testing and Procedures/With Generic Scan Tool/Diagnostic Mode 5: Check
Output of Oxygen Sensor Signals

If specified values are obtained:

-

End diagnosis and switch ignition off.

If specified values are not obtained:

-

End diagnosis and let engine continue to run at idle.

-

Check primary voltage

Checking primary voltage

Vehicles with engine code AEB

Oxygen Sensor (O2S) and Oxygen Sensor Control Before Three Way Catalytic Converter (TWC), Checking|Page 5375 > < Diagram Information and Instructions|Page 5372