Page 3
background image

If voltage supply and wires are OK:

-

Switch ignition on.

-

Connect multimeter to terminal 4 of connector and engine Ground (GND) for voltage measurement:
Specified value: 4.5 to 5.5 V

If there is no voltage:

-

Switch ignition off.

-

Check signal and ground wires

Checking signal and Ground wires of Mass Air Flow (MAF) Sensor

-

Connect test box to control module wiring harness, connect test box for wiring test. Engine Control Module ECM) is not connected. See:
Computers and Control Systems/Testing and Inspection/Reading and Clearing Diagnostic Trouble Codes/Scan Tool Connecting/Test Box,
Connecting For Wiring Test

Vehicles with engine code AEB

-

Check wires between test box and 4-pin connector for open circuit according to wiring diagram.
Terminal 4 + socket 13
Terminal 2 + socket 12
Wire resistance: max: 1.5 ohms

Vehicles with engine code ATW, AUG, AWM

With Manufacturer's Scan Tool|Page 6378 > < With Manufacturer's Scan Tool|Page 6376