volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

With Generic Scan Tool|Page 1408 > < With Generic Scan Tool
Page 2
background image

-

Check for open circuits in wires between test box and connector according to wiring diagram.
Terminal 1 + socket 11
Terminal 2 + socket 76
Terminal 3 + socket 67
Wire resistance: max: 1.5 ohms

Vehicles with engine code ATW, AUG, AWM

-

Check for open circuits in wires between test box and connector according to wiring diagram.
Terminal 1 + socket 98
Terminal 2 + socket 86
Terminal 3 + socket 108
Wire resistance: max: 1.5 ohms

Continued for all vehicles

-

Check wires for short circuit to each other.
Specified value: Infinite ohms

If no malfunctions are found in the wires and there was voltage between terminals 1 + 3:

-

Replace Camshaft Position (CMP) sensor.

-

Erase DTC memory of Engine Control Module (ECM). Diagnostic mode 4: Reset/erase diagnostic data. See: Powertrain Management/Computers
and Control Systems/Testing and Inspection/Scan Tool Testing and Procedures/With Generic Scan Tool/Diagnostic Mode 4: Reset/Erase
Diagnostic Data

-

Generate readiness code. See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles and
Readiness Codes

If no malfunctions are found in wires and there was no voltage between terminals 1 + 3:

-

Replace Engine Control Module (ECM)

With Generic Scan Tool|Page 1408 > < With Generic Scan Tool