First disconnect negative (-) terminal -arrow- from battery.

-

Then disconnect positive ( B+ ) terminal from battery.

Battery, reconnecting

CAUTION:  In order to prevent damage to the battery housing, battery terminals must be placed on battery posts without using force (by hand only).

NOTE:  Battery posts and terminals must no longer be greased.

-

Refit battery positive ( B+ ) terminal on battery positive post.

-

Torque positive ( B+ ) terminal clamp fastener to 5 Nm.

-

Only after the positive ( B+ ) terminal has been secured should the negative (-) terminal clamp be installed.

-

Torque negative (-) terminal clamp fastener to 5 Nm.

-

Perform work steps specified in table.

Work steps required after reconnecting battery