press Q button to enter input

-

press --> key

-

press 0 and 8 buttons to select function "read measurement block"

-

press Q button to enter input
-

display will appear as shown

Read measuring value block

HELP 

Input display group number X

-

press 0 button twice to select "Display group 00"
-

0 display will appear as shown

Read measurement block

Input display group number 00

-

press Q button to enter input
-

display will appear as shown

Read measurement block

-->

1

10

Continue with testing if the value displayed in channel 1 is less than 63 which corresponds to a coolant temperature of at least 80°C (176°F)
-

read OXS signal value in channel 6
-

display must fluctuate

If YES
-

press --> button.

-

press 0 and 6 button to select function "end output"

-

press Q button to enter input

If display does NOT fluctuate

disconnect OXS sensor (4-pin) and OXS heater harness connectors
- mounted on right engine mount (arrow)

touch violet wire from control unit (arrow) to ground for approx. 20 seconds using jumper wires from VW 1594 adaptor kit

value displayed in channel 6 must increase

If YES

replace OXS sensor (G 39)

read and then erase Fault memory

If display value does not increase