volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

A/T - Diagnosis/Measuring Block Values|Page 6687 > < A/T - Diagnosis/Measuring Block Values|Page 6685
Page 6
background image

The ten value readouts shown correspond in order to the ten channel numbers in the chart that follows this page.

^ observe values shown on tester and compare with values in chart

^

if specified values appear in all channels press

-->

key; problem has not been found using this test sequence

^

if specified values are not observed, conduct return to basic setting (see section D3-80 in Repair Manual) and follow instructions in chart for
further testing to locate source of problem (see Repair Manual section D3-70 for electrical test steps)

Individual Measuring Values, Reading

Individual measuring values, reading

After connecting the tester VAG 1551 and selecting the "Transmission electronics" program (see Repair Manual microfiche, Group D3, the individual
measuring values can be read as follows:

^

read display

^

press keys 0 and 9 (this selects function 09 for reading individual measuring values)

^

read display

^

press Q key to acknowledge input

^

read display

^

press keys to input channel number of desired readout:

A/T - Diagnosis/Measuring Block Values|Page 6687 > < A/T - Diagnosis/Measuring Block Values|Page 6685