volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Combi-Valve Checking|Page 5807 > < Combi-Valve Checking|Page 5805
Page 1
background image

Air Injection Control Valve: Testing and Inspection
Combination Valves, Checking

Combination Valves, Checking

Recommended special tools and equipment

-

V.A.G 1390 Hand Vacuum Pump

Test requirements

-

No leaks in vacuum lines or hose connections.

-

Vacuum hoses not clogged or kinked

-

Pressure hose for Secondary Air Injection (AIR) Pump Motor not clogged or kinked

Test sequence

-

Disconnect vacuum hose of the combination valve to be checked at Y-piece (arrow).

-

Connect V.A.G 1390 hand vacuum pump to vacuum hose of the valve to be checked.

NOTE:  Do not use pressurized air for the following test.

-

Remove front noise insulation.

-

Disconnect pressure hose (arrow) between Secondary Air Injection (AIR) Pump Motor and connecting line and blow into it with light pressure.
Both combination valves must be closed.