Leak Detection Pump (LDP) -V144-, Checking
Recommended special tools and equipment
-
V.A.G 1526 multimeter or V.A.G 1715 multimeter
-
V.A.G 1594 connector test kit
-
Wiring diagram
Test requirements
-
The respective fuses of Leak Detection Pump (LDP) -V144- must be OK
-
Ignition switched off.
Test sequence
-
Remove wheel housing liner, rear left.
-
Disconnect 3-pin connector of Leak Detection Pump (LDP) -V144- (arrow).
-
Measure resistance between terminals 1 + 3 of diagnostic pump.
Specified value: 640 to 720 ohms
-
Measure resistance between terminals 2 + 3 of diagnostic pump.
Specified value: 17.5 to 19.5 ohms