Passat V6-2.8L (ATQ) (2004)
-
Coolant temperature must be at least 80 °C, See Display group 04, display field 3
Test sequence
-
Connect V.A.G 1551 scan tool (VAG 1552). Start engine and select Engine Control Module (ECM) using address word 01 (connecting scan tool
and selecting ECM). See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Reading and Clearing Diagnostic
Trouble Codes/Scan Tool Connecting/With Manufacturer's Scan Tool/Connecting VAG 1551 Scan Tool
Indicated on display
Rapid data transfer
HELP
Select function XX
-
Press 0 and 8 of function "Read Measuring Value Block", and then press Q to exit from input mode.
Indicated on display
Read Measuring Value Block
Input display group number XXX
-
Press 0, 0 and 5 for the function "display group number 5", and then press Q to exit from input mode.
Indicated on display (1 - 4 = display fields)
Read Measuring Value Block 5
->
1
2
3
4
-
Check if control module recognizes operating conditions (display field 4).
-
Idle: (as long as the engine is idling, "idle" should be indicated)
Display: Idle
-
Deceleration mode:
-
Increase engine speed to above 3000 RPM.
-
Then abruptly close throttle valve (as long as engine speed is over 1400 RPM, "Deceleration mode" should be indicated).
Display: Deceleration
NOTE: Below 1400 RPM idle will be recognized again.
-
Partial throttle:
-
Hold gas pedal steady (as long as gas pedal is held steady, "partial throttle" should be indicated).
Display: Partial throttle
-
Enrichment:
-
Open throttle all the way (as far as throttle valve goes).
Acceleration enrichment should be briefly indicated
Display: Enrich
Observe safety precautions which apply to road tests.
-
Press -> button.
-
Press buttons -0- and -6- to select "End data transfer" function 06. Press -Q- button to confirm input.
If expected values are not obtained:
-
Check DTC memory, repair any malfunctions and then erase DTC memory.
-
Test throttle valve control module. See: Electronic Throttle Control Module/Testing and Inspection
Procedure After Interruption of Voltage Supply
Procedure after interruption of voltage supply