Readiness Codes 

Oxygen Sensors and Oxygen Sensor Regulation Before Catalytic Converter, Checking

Oxygen Sensors And Oxygen Sensor Regulation Before Catalytic Converter, Checking

NOTE:  When servicing terminals in harness connector of oxygen sensor, use only gold-plated terminals.

Recommended special tools and equipment

-

V.A.G 1526 multimeter or V.A.G 1715 multimeter

-

V.A.G 1594 connector test kit

-

Wiring diagram

Test requirements

-

The respective fuses of Heated Oxygen Sensor (HO2S) -G39- and Heated Oxygen Sensor (HO2S) 2 -G108- must be OK

-

Battery voltage must be at least 11.5 volts.

-

All electrical consumers such as, lights and rear window defroster must be switched off.

-

Parking brake must be engaged or else daylight driving lights will be switched on.

-

If vehicle is equipped with an A/C system, it must be switched off.

-

Ground (GND) connections between engine and chassis must be OK.

-

Exhaust system must be properly sealed between catalytic converter and cylinder head.

-

Coolant temperature must be at least 80 degrees C. Diagnostic mode 1: Check measured values; PID 5, Coolant temperature. See: Powertrain
Management/Computers and Control Systems/Testing and Inspection/Scan Tool Testing and Procedures/With Generic Scan Tool/Diagnostic
Mode 1: Check Measuring Values

-

Oxygen sensor heaters for oxygen sensors before catalytic converter must be OK, check.

Function test

-

Select the following output of oxygen sensor signals and check whether the specified values are being reached. Diagnostic mode 5: Check output
of oxygen sensor signals. See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Scan Tool Testing and
Procedures/With Generic Scan Tool/Diagnostic Mode 5: Check Output of Oxygen Sensor Signals

If specified values are obtained:

-

End diagnosis and switch ignition off.

If specified values are not obtained:

-

End diagnosis and let engine continue to run at idle.

-

Check primary voltage.

Checking primary voltage

-

Disconnect 4-pin harness connector to the respective oxygen sensor:

Heated Oxygen Sensor After Three Way Catalytic Converter, Check|Page 1704 > < Heated Oxygen Sensor After Three Way Catalytic Converter, Check|Page 1702