Passat GLS L4-1.8L Turbo (AUG) (2001)
Indicated on display
Rapid data transfer
HELP
Select function XX
-
A button must be pressed once on each of the radio frequency keys to be "learned" (in example above, 3 keys).
-
Switch off ignition and remove ignition key.
-
Perform functional check (e.g. 3) of radio frequency keys.
NOTE:
-
All 3 keys (See example) can be "learned" in one matching sequence.
-
15 seconds must not be exceeded when matching all ignition keys (pressing a button).
-
A successful adaptation can be determined via Read Measured Value Block, function 08, display group number 013. When operation the radio
frequency unit both of first measurement values must have the status OK. Simultaneously the last measurement value will show the positional
number of the key (i.e. first, second, third, fourth key).
-
If the remote control key is operated several times the third display "no measured value" changes to "OK".
The matching of ignition keys is automatically terminated when:
-
Number of keys to be matched is reached.
-
A button of one of the keys to be "learned" is pressed frequently.
-
Permissible matching period of 15 seconds is exceeded (DTC is stored).
-
Select function 02 "Check DTC Memory". If there is no DTC stored, the matching of the keys has been successfully completed.
-
Press keys -0- and -6- to end the output.
Indicated on display
Rapid data transfer
Q
06 - End output
-
Confirm with -Q- key.
Indicated on display
Rapid data transfer
HELP
Enter address word XX
-
Switch off ignition.
-
Disconnect connector to VAG 1551 Scan Tool.