Passat GLS Wagon L4-1.8L Turbo (AUG) (2001)
Air Diverter Valve: Testing and Inspection
Combination valve, checking
Special tools and equipment
^
VAG1390 hand vacuum pump
Test requirements
^
No DTCs in DTC memory:
^
Output Diagnostic Test Mode (DTM) performed:
^
No leaks in vacuum lines or hose connections
^
Vacuum hoses not clogged or kinked
Test sequence
-
Disconnect vacuum hose at combination valve (arrow) and connect VAG1390 vacuum pump.
Note: Do not use pressurized air for the following test!
-
Disconnect pressure hose (arrow) at Secondary Air Injection (AIR) pump motor and blow air in with light pressure. Combination valve must