Evaporator Case > < Sender For Outlet Temperature, Floor Outlet -G192-
Page 1
background image

Discharge Air Temperature Sensor / Switch: Service and Repair
Sender For Outlet Temperature, Center -G191-

Sender For Outlet Temperature, Center -G191, Removing

CAUTION!

-

Before working on the electrical system, obtain radio security code and disconnect battery Ground (GND) strap.

-

When reconnecting battery, always check operation of vehicle equipment such as radio, clock, and power windows.

-

Remove radio

-

Remove Climatronic control module -J255- 

-

Remove center trim 

-

Disconnect electrical connector -2- from sender -G191-.

-

Rotate sender -1-, 90° -arrow A- and remove from housing -3-.