volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 4511 > < Initial Inspection and Diagnostic Overview|Page 4509
Page 1
background image

Information Bus: Testing and Inspection

From 10.00

CAN-bus On Board Diagnostic (OBD) interface -J533- ("Gateway") 
The instrument cluster is connected to the powertrain CAN-bus and convenience system CAN-bus. 

The databus is also referred to as the CAN databus.
 
Data can be transmitted between the CAN-bus and the diagnostic wire (K wire) via the databus On Board Diagnostic (OBD) interface -J533-. 

The CAN-bus On Board Diagnostic (OBD) interface -J533- must be coded according to vehicle equipment when instrument cluster is replaced.

The CAN-bus On Board Diagnostic (OBD) interface -J533- in the instrument cluster has its own diagnostic address. 

NOTE: 
The following description refers only to the VAG 1551 Scan Tool (ST). 

Connecting VAG 1551 Scan Tool (ST) and selecting functions (checking module version)

NOTE:  Connect Scan Tool (ST). Refer to "Scan Tool Testing/Scan Tool Connecting and Initial Checks/Scan Tool(ST), Connecting" under
"Accessories and Optional Equipment/Alarm Module, (Vehicle Antitheft)"    

-

Switch on ignition.

Indicated on display:

VAG - On Board Diagnostic (OBD)

HELP

1- Rapid data transfer*
2- Blink code output*

-

* Two operating modes are displayed alternately

-

Connect VAG 1551 Scan Tool (ST), select operating mode 1 "Rapid data transfer",switch on ignition and enter address word 19 for "gateway".

Indicated on display:

Rapid data transfer

HELP

Enter address word XX

-

Press buttons -1 - and 9-. "19" is the address word for "gateway".

Indicated on display:

Rapid data transfer

Q

19 Gateway

-

Press -Q- button to confirm input.

Indicated on display:

Rapid data transfer

Q

Scan tool sends address word 19

Indicated on display:

6N0909901 Gateway K <-> CAN

0001

Coding XXXXX WSC 00000

-

Upper line

Ident no. of control module, System identification (Gateway K <-> CAN)2), Version number

-

Bottom line  Coding number1), Work Shop Code 

1) depends on control modules connected to CAN-bus

Initial Inspection and Diagnostic Overview|Page 4511 > < Initial Inspection and Diagnostic Overview|Page 4509