volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Heated Oxygen Sensor After Three Way Catalytic Converter, Check|Page 4633 > < Heated Oxygen Sensor After Three Way Catalytic Converter, Check|Page 4631
Page 7
background image

Read Measuring Value Block 32

->

1

2

3

4

-

Check idle oxygen sensor adaptation values (additive) in display fields 1 and 3.
Specification: -10.0 to 10.0%

-

Check partial throttle oxygen sensor adaptation values (multiplicative) in display fields 2 and 4.
Specification: -10.0 to 10.0%

If the expected value(s) are not obtained: Refer to Scan Tool Testing/Measuring Value Blocks (Function 08)/Evaluating Display Groups 30-44, 99 See:
Testing and Inspection 

If specified values are obtained:

-

Change to display group 33 as follows:

V.A.G 1551: Press button -3- 
VAG 1552: up arrow key is pressed

Indicated on display (1 - 4 = display fields)

Read Measuring Value Block 33

->

1

2

3

4

-

Observe oxygen sensor control in display fields 1 and 3.

The indication should oscillate in the range from -10.0 to 10.0% by at least 2%.

-

Check oxygen sensor voltage in display fields 2 and 4.

The voltage should oscillate at least 20 times a minute in the range from 0 to 1.0 V.

If one or more of the indications in display field 2 or 4 is constant on one value:

-

Continue testing according to following table.

Heated Oxygen Sensor After Three Way Catalytic Converter, Check|Page 4633 > < Heated Oxygen Sensor After Three Way Catalytic Converter, Check|Page 4631