Continuation for all vehicles

If specified value is not obtained:

-

Measure resistance for sensor heater at connector to oxygen sensor terminal 1 + 2.
Specified value: max: 200 Ohms

-

Replace the respective oxygen sensor:
-

Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) -G130-, bank 1, item 4

-

Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) -G131-, bank 2, item 11

-

Erase DTC memory of Engine Control Module (ECM), Diagnostic mode 4: Reset/erase diagnostic data.

-

Generate readiness code.  See: Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes

If specified value is obtained:

-

Check Ground (GND) activation of the respective oxygen sensor heater.

-

Connect test box to control module wiring harness, connect test box for wiring test.  See: Testing and Inspection/Reading and Clearing Diagnostic
Trouble Codes/Scan Tool Connecting/With Generic Scan Tool/Test Box, Connecting For Wiring Test

-

Check wires between test box and 4-pin connector to Engine Control Module (ECM) for open circuit according to wiring diagram.
Wire resistance: max: 1.5 Ohms

Vehicles with engine code AHA

Vehicles with engine code ATQ