Oxygen Sensor: Testing and Inspection
Oxygen Sensor & O2S Control Behind Three Way Catalytic Converter (TWC), Checking

With Generic Scan Tool

Oxygen Sensor and oxygen sensor control behind Three Way Catalytic Converter (TWC), checking

NOTE:  When servicing terminals in harness connector of Heated Oxygen Sensor (HO2S), use only gold plated terminals.

Recommended special tools and equipment

-

V.A.G 1526 multimeter or V.A.G 1715 multimeter

-

V.A.G 1594 Connector test set

-

Wiring diagram

Test requirements

-

The respective fuses of Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) -G130- and Oxygen Sensor (O2S) 2 Behind Three
Way Catalytic Converter (TWC) -G131- must be OK:

-

Battery voltage must be at least 11.5 volts.

-

All electrical consumers like, for example, lights and rear window heating must be switched off.

-

Parking brake must be engaged or else daylight driving lights will be switched on.

-

If vehicle is equipped with an A/C system, it must be switched off.

-

Ground (GND) connections between engine and chassis must be OK.

-

Exhaust system must be properly sealed between catalytic converter and cylinder head.

-

Coolant temperature must be at least 80 degrees C, Diagnostic mode 1: Check measuring values; PID 5, Coolant temperature.  Refer to "Scan
Tool Testing/Diagnostic Mode 1: Check Measuring Values".

See: Testing and Inspection/Scan Tool Testing and Procedures/With Generic Scan Tool/Diagnostic Mode 1: Check Measuring Values  

-

Oxygen sensor heater for oxygen sensors behind catalytic converter must be OK, check  

Function test

-

Select the following output of oxygen sensor signals and check whether the specified values are being reached, Diagnostic mode 5: Check output
of oxygen sensor signals.  Refer to "Scan Tool Testing/Diagnostic Mode 5: Check Output of Oxygen Sensor Signals"  

See: Testing and Inspection/Scan Tool Testing and Procedures/With Generic Scan Tool/Diagnostic Mode 5: Check Output of Oxygen Sensor Signals

-

Check the specified values of the output of oxygen sensor signals at idle:
*) V = Voltage in Volts (oxygen sensor signal)
**) t = Time in seconds

Heated Oxygen Sensor After Three Way Catalytic Converter, Check|Page 5117 > < Heated Oxygen Sensor After Three Way Catalytic Converter, Check|Page 5115