volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Heated Oxygen Sensor After Three Way Catalytic Converter, Check|Page 5127 > < Heated Oxygen Sensor After Three Way Catalytic Converter, Check|Page 5125
Page 1
background image

Oxygen Sensor: Testing and Inspection
Oxygen Sensor Aging, Bank 1, Sensor 1, Checking

Heated Oxygen Sensor (HO2S) aging, bank 1 sensor 1, checking

Special tools and equipment

-

VAG 1788/10 RPM adjuster

-

V.A.G 1551 Scan Tool (or VAG 1552) with VAG 1551/3 cable

Test condition

-

Coolant temperature must be at least 85°C, See display group 04, display field 3

Function test

-

Connect V.A.G 1551 scan tool (VAG 1552). Start engine and select Engine Control Module (ECM) using address word 01. Refer to Scan Tool
Testing/Scan Tool Connecting and Initial Checks/Connecting V.A.G 1551 Scan Tool See: Testing and Inspection/Reading and Clearing
Diagnostic Trouble Codes/Scan Tool Connecting/With Manufacturer's Scan Tool/Connecting VAG 1551 Scan Tool 

Indicated on display

Rapid data transfer

HELP

Select function XX

-

Press buttons -0- and -4- to select "Basic Setting" function 04. Press -Q- button to confirm input.

Indicated on display

Basic Setting
Input display group number XXX

-

Press buttons -0-, -3- and -4- to select "Display group number 34". Press -Q- button to confirm input.

Indicated on display (1 - 4 = display fields)

System in Basic Setting 34

->

1

2

3

4

-

Use VAG 1788/10 RPM adjuster to adjust engine RPM to 1000-2400 RPM:

-

Hold RPM until the catalytic converter temperature in display field 2 over 350°C climbs.

-

Check specified values in display fields 1 - 4.

If diagnostic is initiated by the Engine Control Module (ECM), the indication in display field 4 will jump from "Test OFF" to "Test ON".

-

Continue to hold the RPM at 1000 - 2400 until in display field 4 expected value "B1-S1 OK" is indicated.

If specified values are not obtained:

Heated Oxygen Sensor After Three Way Catalytic Converter, Check|Page 5127 > < Heated Oxygen Sensor After Three Way Catalytic Converter, Check|Page 5125