Readiness Codes 

Running Characteristics After Cold Start, Checking

Running Characteristics After Cold Start, Checking

If problems occur after a cold start, it is necessary to check whether they occur before or after the oxygen sensor control starts.

Oxygen sensor control starts when the required oxygen sensor temperature of approx. 300°C is reached.

The time which passes before this temperature is reached is influenced mainly by the following factors:

-

Ambient temperature (summer/winter)

-

Operating conditions after start

-

Function of oxygen sensor heater

Test condition

-

No DTCs are stored concerning oxygen sensor control, Querying DTC Memory Refer to Displaying and Reading Trouble Codes/With
Manufacturer Scan Tool/DTC Memory Checking and Erasing See: Powertrain Management/Computers and Control Systems/Testing and
Inspection/Reading and Clearing Diagnostic Trouble Codes/Reading Diagnostic Trouble Codes/With Manufacturer's Scan Tool/DTC Memory
Checking and Erasing

Test sequence

Test vehicle under cold start conditions in a road test.

NOTE:  The road test requires a 2nd person.

WARNING! The scan tool must be secured to the rear seat and operated by a second technician from there.

-

Connect V.A.G 1551 scan tool (VAG 1552). Start engine and select Engine Control Module (ECM) using address word 01. Refer to Scan Tool
Testing/Scan Tool Connecting and Initial Checks/Connecting V.A.G 1551 Scan Tool See: Powertrain Management/Computers and Control
Systems/Testing and Inspection/Reading and Clearing Diagnostic Trouble Codes/Scan Tool Connecting/With Manufacturer's Scan
Tool/Connecting VAG 1551 Scan Tool 

Indicated on display

Rapid data transfer

HELP

Select function XX

-

Press buttons -0- and -8- to select "Read measuring value block" function 08. Press -Q- button to confirm input.

Indicated on display

Read Measuring Value Block

HELP

Input display group number XXX

-

Press 0, 3 and 1 for the function "display group number 31", and then press Q to exit from input mode.

Indicated on display (1 - 4 = display fields)

Read Measuring Value Block 31

->

1

2

3

4

-

Now perform road test and observe oxygen sensor voltage in display fields 1 (sensor 1) and 3 (sensor 2).

When vehicle is cold or when oxygen sensor control is not operating, voltage should be: 0.45-0.50 V
When oxygen sensor control starts, voltage signal in display fields 1 and 3 should oscillate between 0.0-1.1 V.

Read Measuring Value Block 31

->

1

2

3

4

NOTE:

-

Voltage values over 0.7 V mean that mixture is rich.

-

Voltage values below 0.3 V mean that mixture is lean.