4

- Check specifications in Display zones 3 and 4. 

If specification obtained 

-

Press -> button. 

-

Press 0 and 6 buttons to select Function 06 "End data transfer"

- Press Q button to enter input 
- Switch OFF ignition. 

Continuation 

-

Disconnect 4-pin harness connector (black) to Oxygen sensor -1- G108 (after Three Way Catalyst).

-

Switch Multimeter to "Resistance" range 

-

Connect Multimeter between terminals 1 + 2 of Oxygen sensor connector using jumper wires from VW 1594 adaptor kit.