Page 8
background image

 

-

Switch multimeter to Voltage measurement range 

-

Connect Multimeter between terminals 3 + 4 of ECM connector using jumper wires from VW 1594 adaptor kit 

-

Start engine and measure basic Voltage.
-

Specification: 0.40 to 0.50 Volts 

-

Switch OFF ignition. 

If specification not obtained 

-

Check Oxygen sensor wiring.

If specification obtained
 

-

Replace Oxygen sensor G39 (before Three Way Catalyst). 

Oxygen sensor wiring, checking 

-

Connect VAG 1598/22 Test Box to Engine Control Module harness connector. 