Specified value: 22,0 to 30,0 ohms.

If the specified value is not obtained:

-

Replace the Evaporative Emission (EVAP) Canister Purge Regulator Valve (N80). 

If the specification is obtained:

Checking voltage supply

-

Using a Multimeter, check the electrical harness connector terminal 1 to Ground (GND) for voltage.

-

Operate the starter briefly.

Specified value: battery voltage.

If the specified value was not obtained:

-

Check the wiring from the Evaporative Emission (EVAP) Canister Purge Regulator Valve (N80) electrical harness connector terminal 1 to the
Motronic Engine Control Module (ECM) Power Supply Relay 2 (J670) socket 2/87 for an open circuit or a to short circuit to Ground (GND).

-

Check the electrical harness connectors for damage, corrosion, loose or broken terminals.

-

If necessary, repair the wiring connection.

If the specified value was obtained:

Checking Ground (GND