Passat Sedan L4-2.0L Turbo (BPY) (2007)
Specified value: 22,0 to 30,0 ohms.
If the specified value is not obtained:
-
Replace the Evaporative Emission (EVAP) Canister Purge Regulator Valve (N80).
If the specification is obtained:
Checking voltage supply
-
Using a Multimeter, check the electrical harness connector terminal 1 to Ground (GND) for voltage.
-
Operate the starter briefly.
Specified value: battery voltage.
If the specified value was not obtained:
-
Check the wiring from the Evaporative Emission (EVAP) Canister Purge Regulator Valve (N80) electrical harness connector terminal 1 to the
Motronic Engine Control Module (ECM) Power Supply Relay 2 (J670) socket 2/87 for an open circuit or a to short circuit to Ground (GND).
-
Check the electrical harness connectors for damage, corrosion, loose or broken terminals.
-
If necessary, repair the wiring connection.
If the specified value was obtained:
Checking Ground (GND
If the manufacturers test box is being used. Perform the following step.