Page 2
background image

Display Group 35

-

Press -> button.

-

Press buttons -0- and -6- to select "End Output" function 06, and press -Q- button to confirm input.

-

Switch ignition off.

Continuation

If displayed values are NOT OK (not as specified):

-

Road test to condition oxygen sensor (eliminate possible contamination) and repeat test.

WARNING!

When driving or riding in an airbag-equipped vehicle, NEVER hold the scan tool or other test equipment in your hands or lap
while in motion. Objects between you and the airbag increase the risk of injury in an accident.
During a test drive in an airbag-equipped vehicle, test equipment must always be fastened to and operated from the rear seat by a
second technician.

If displayed value is still NOT OK:

-

Replace HO2S -G108-.

-

Check readiness code. If DTC memory was erased or the ECM disconnected, generate new readiness code.   See: Computers and Control
Systems/Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes 