Passat Sedan V6-3.6L (BLV) (2008)
-
Loose the right support - 1 - from the assembly carrier.
-
Disconnect harness connector from Right Temperature Door Motor (V159).
-
Remove securing bolts - 1 - and remove Right Temperature Door Motor (V159).
-
Unhook brace - 2 - from Right Temperature Door Motor (V159).
Installing
Install in reverse order of removal.
‹› After installing the right temperature regulator door motor (V159), recirculating air door must be checked for function.
‹› Initiate "Basic Setting" function with Vehicle Diagnosis, Testing and Information System (VAS 5051B) (or succeeding model). Refer to => [
Climatronic A/C System, Checking and Adjusting Components ] See: Testing and Inspection/Component Tests and General
Diagnostics/Climatronic A/C System, Checking and Adjusting Components.
Indirect Ventilation Door Motor
Door Motors
Special tools, testers and auxiliary items required
‹› Vehicle diagnosis, testing and information system (VAS 5051B) or newer model.
Perform following work first: