volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Air Door Cable, HVAC|Testing and Inspection|Page 6456 > < Fresh/Recirculating Air Door Motor|Page 6452
Page 1
background image

Air Door Cable: Testing and Inspection

Flexible Shaft, Checking

Flexible shaft for adjusting unit of air distribution doors:

-

Let fresh air blower run on highest speed. If air flows out of defroster vents in the "Defrost" position and no airflows out of footwell vents,
installation of flexible shaft is correct. If this is not the case, remove flexible shaft from adapter. Place controls for heating and A/C system,
Climatic onto adapter and rotate rotary knob for air distribution 1/2 rotation (180 degrees). Then re-connect flexible shaft. Repeat test

Air Door Cable, HVAC|Testing and Inspection|Page 6456 > < Fresh/Recirculating Air Door Motor|Page 6452