volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

HO2S Front Oxygen Sensor Bank 1 Sensor 1, Checking|Page 3143 > < HO2S Front Oxygen Sensor Bank 1 Sensor 1, Checking|Page 3141
Page 17
background image

‹› Ignition switched off.

Test procedure

-

Observe safety precautions. Refer to => [ Safety Precautions ] See: Service Precautions/Safety Precautions

-

Observe Clean Working Conditions. Refer to => [ Clean Working Conditions ] See: Service Precautions/Clean Working Conditions

-

Perform a preliminary check to verify the customers complaint. Refer to => [ Preliminary Check ] See: Testing and Inspection/Scan Tool Testing
and Procedures/Preliminary Check.

Start diagnosis

Checking internal resistance

-

Disconnect the HO2S Oxygen Sensor Bank 1 Sensor 2 (G130) electrical harness connector - 1 -.

-

Using a multimeter, check the Oxygen Sensor Heater Bank 1 Sensor 2 (Z29) terminals 1 to 2 for resistance.

Specified value: 1.0 to 20.0 ohms (at approx. 20° C)

If the specification was not obtained:

-

Replace the faulty HO2S Oxygen Sensor Bank 1 Sensor 2 (G130). Refer to the Repair Information.

If the specification was obtained:

Checking voltage supply