Tightening specification of the plenum chamber bracket nuts: 6 Nm.

-

Connect the connector on the ECM and slide the latches -  1 - inward.

-

Take a new locking bracket and tighten the new shear bolts evenly until the bolt heads shear off.

-

Install the plenum chamber cover.

-

Install the windshield wiper arms.