volkswagen Workshop Repair Guides

Volkswagen Workshop Service and Repair Manuals

Components, Checking|Page 2828 > < Components, Checking
Page 2
background image

-

Disconnect 6-pin harness connector to the respective oxygen sensor:
-

Heated Oxygen Sensor (HO2S) -G39-, bank 1 6-pin harness connector (black) -1-,

-

Heated Oxygen Sensor (HO2S) 2 -G108-, bank 2 6-pin harness connector (brown) -2-.

NOTE:

-

Bank 1 = Cylinder bank 1, in direction of travel, right

-

Bank 2 = Cylinder bank 2, in direction of travel, left

Checking voltage supply and wiring to control module

-

Connect multimeter to terminals 3 + 4 of connector to Engine Control Module (ECM) for voltage measurement.

-

Start engine, and let run at idle.
Specified value: at least 7.0 V

If specified value is obtained:

-

Switch ignition off.

-

Erase DTC memory of Engine Control Module (ECM), Diagnostic mode 4: Reset/erase diagnostic data.

-

Generate readiness code.  See: Testing and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes

If specified value is not obtained:

-

Connect multimeter to terminal 3 of connector to Engine Control Module (ECM) + Ground (GND) for voltage measurement.
Specified value: at least 11.0 V

-

Switch ignition off.

Components, Checking|Page 2828 > < Components, Checking