Function test

-

Select the lambda test results and check whether the specified values are being reached, Diagnostic mode 5: Check output of oxygen sensor
signals.  Refer to "Scan Tool Testing/Diagnostic Mode 5: Check Output of Oxygen Sensor Signals" 

 See: Computers and Control Systems/Testing and Inspection/Scan Tool Testing and Procedures/Diagnostic Mode 5: Check Output of Oxygen Sensor
Signals

-

End diagnostic and switch ignition off.

If specified values are not obtained:

Checking oxygen sensor wires

-

Connect test box to control module wiring harness, connect test box for wiring test.  Refer to "Scan Tool Connecting/Test Box, Connecting For
Wiring Test".  See: Computers and Control Systems/Testing and Inspection/Reading and Clearing Diagnostic Trouble Codes/Scan Tool
Connecting/With Generic Scan Tool/Test Box, Connecting For Wiring Test

-

Disconnect 6-pin harness connector to the respective oxygen sensor:
-

Heated Oxygen Sensor (HO2S) -G39-, bank 1 6-pin harness connector (black) -1-,

-

Heated Oxygen Sensor (HO2S) 2 -G108-, bank 2 6-pin harness connector (brown) -2-.

NOTE:

-

Bank 1 = Cylinder bank 1, in direction of travel, right

-

Bank 2 = Cylinder bank 2, in direction of travel, left

-

Check wires between test box and 6-pin connector to Engine Control Module (ECM) for open circuit according to wiring diagram.
Wire resistance: max. 1.5 Ohms