Indicated on display:
Rapid data transfer
HELP
Select function XX
-
Press buttons -0- and -8- to select function 08, "Read measuring value block".
Indicated on display:
Rapid data transfer
Q
08 - Read measuring value block
-
Press -Q- button to confirm
Indicated on display:
Read measuring value block
Q
Enter display group number XX
-
Enter desired display group number (from table) and press -Q- button to confirm input.
Indicated on display:
Read measuring value block X
->
1 2 3 4
NOTE:
-
Interpreting measured values in display fields. See: Scan Tool Testing/Measuring Value Block (Function 08)/Evaluating Measured Value Blocks
-
With printer switched on, information in display is printed out.
-
Press -> button if measured value specifications are met in all display fields.
Evaluating Measured Value Blocks
Table Of Selectable Display Group Numbers
Display group number Display field designations
001
1
=
Open
2
=
Power supply voltage
3
=
Illumination in %
4
=
S-contact status (on or off)
002
1
=
Front speakers
2
=
OK, short or open circuit
3
=
Rear speakers
4
=
OK, short or open circuit
003
1
=
Passive or active
2
=
Antenna
3
=
OK, short or open circuit
4
=
Open
004
1
=
0 (Power output to active amplifier OK)
1
=
1 (Power output to active amplifier short to ground)
2
=
Open
3
=
Open
4
=
Open
005
1
=
CD changer installed (even when not coded for CD in radio)
2
=
OK or not OK
3
=
Open
4
=
Open