Passat Syncro Wagon V6-2.8L (ATQ) (2000)
-
Switch off ignition.
-
Disconnect harness connectors for the VAG 1551 scan tool
Reading
Read Measuring Value Block (function 08)
Indicated on display:
Rapid data transfer
HELP
Select function XX
-
Press buttons -0- and -8- to initiate "Read Measuring Value Block", function 08.
Indicated on display:
Rapid data transfer
Q
08 - Read Measuring Value Block
-
Press -Q- button to confirm input.
Indicated on display:
Read Measuring Value Block
Enter display group number XXX
Overview of selectable display group numbers
Display group Display field in display
001
1 = voltage supply in volts
2 = Light switch condition
3 = Speed in km/h
4 = Acceleration in m/s2
002
1 = Voltage of front level sensor in volts
2 = Voltage of level sensor rear, in volts
3 = Specification for actuator motors in %
4 = Time constant in s
-
Select desired display group number and press -Q- button to confirm.