Passat Syncro Wagon V6-2.8L (ATQ) (2000)
Air Injection Vacuum Control Solenoid Valve: Testing and Inspection
With Generic Scan Tool
Secondary Air Injection (AIR) valve, checking
Solenoid valve is closed when no voltage is present.
Recommended special tools and equipment
-
V.A.G 1526 multimeter or V.A.G 1715 multimeter
-
V.A.G 1594 Connector test set
-
Wiring diagram
Test requirements
-
The respective fuses of Secondary Air Injection (AIR) Solenoid Valve -N112- must be OK:
-
Ignition switched off.
Test sequence
-
Disconnect 2-pin connector -1- from Secondary Air Injection (AIR) Solenoid Valve -N112- -2-.
-
Measure resistance between terminals of solenoid valve.
Specified value: 25.0 to 35.0 Ohms
If specified value is not obtained: